Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Braz. j. otorhinolaryngol. (Impr.) ; 77(4): 481-487, July-Aug. 2011. ilus
Article in English | LILACS | ID: lil-595795

ABSTRACT

The electrical stimulation generated by the Cochlear Implant (CI) may improve the neural synchrony and hence contribute to the development of auditory skills in patients with Auditory Neuropathy/Auditory Dyssynchrony (AN/AD). AIM: Prospective cohort cross-sectional study to evaluate the auditory performance and the characteristics of the electrically evoked compound action potential (ECAP) in 18 children with AN/AD and cochlear implants. MATERIAL AND METHODS: The auditory perception was evaluated by sound field thresholds and speech perception tests. To evaluate ECAP's characteristics, the threshold and amplitude of neural response were evaluated at 80Hz and 35Hz. RESULTS: No significant statistical difference was found concerning the development of auditory skills. The ECAP's characteristics differences at 80 and 35Hz stimulation rate were also not statistically significant. CONCLUSIONS: The CI was seen as an efficient resource to develop auditory skills in 94 percent of the AN/AD patients studied. The auditory perception benefits and the possibility to measure ECAP showed that the electrical stimulation could compensate for the neural dyssynchrony caused by the AN/AD. However, a unique clinical procedure cannot be proposed at this point. Therefore, a careful and complete evaluation of each AN/AD patient before recommending a Cochlear Implant is advised. Clinical Trials: NCT01023932.


A estimulação elétrica gerada pelo Implante Coclear (IC) pode ser capaz de melhorar a sincronia neural e contribuir para o desenvolvimento das habilidades auditivas de sujeitos portadores de Neuropatia Auditiva/Dessincronia Auditiva (NA/DA). OBJETIVO: Estudo de coorte prospectivo transversal para avaliar o desempenho auditivo e as características do Potencial de Ação Composto Eletricamente Evocado no Nervo Auditivo (ECAP) em 18 crianças portadoras de NA/DA e usuárias de IC. MATERIAL E MÉTODOS: Percepção auditiva e características do ECAP foram avaliadas respectivamente, por meio da determinação dos limiares tonais e testes de percepção de fala e pelas medidas de limiar e amplitude da resposta neural para as frequências de estimulação de 35 e 80Hz. Não foram encontradas diferenças estatisticamente significativas no desenvolvimento das habilidades auditivas entre os sujeitos avaliados. RESULTADOS: Não foram observadas modificações estatisticamente significativas nas características de limiar e amplitude do ECAP para as duas frequências de estimulação testadas. CONCLUSÕES: O IC caracterizou-se como um efetivo recurso para o desenvolvimento das habilidades auditivas em 94 por cento dos sujeitos, sendo a estimulação elétrica capaz de compensar a alteração da sincronia neural decorrente da NA/DA. A avaliação criteriosa de cada caso de maneira específica deve ser realizada no momento anterior à indicação cirúrgica. Clinical Trials: NCT01023932.


Subject(s)
Child , Child, Preschool , Humans , Infant , Auditory Perceptual Disorders/surgery , Cochlear Implantation , Evoked Potentials, Auditory, Brain Stem/physiology , Hearing Loss, Sensorineural/surgery , Vestibulocochlear Nerve Diseases/surgery , Auditory Perceptual Disorders/physiopathology , Cohort Studies , Cross-Sectional Studies , Electric Stimulation , Electrophysiology , Hearing Loss, Sensorineural/physiopathology , Prospective Studies , Vestibulocochlear Nerve Diseases/physiopathology
2.
Repert. med. cir ; 15(2): 77-81, 2006. graf, tab
Article in Spanish | LILACS, COLNAL | ID: lil-523255

ABSTRACT

Objetivo: describir los resultados obtenidos con la colocación de dos prótesis estapediales a pacientes sometidos a estapedotomía por otosclerosis. Tipo de estudio: descriptivo y retrospectivo de revisión de casos. Métodos: se utilizaron prótesis de titanio y de teflón-platino para el cierre de la diferencia entre las curvas ósea y aérea (gap) producido por la otosclerosis. Se revisaron 70 casos intervenidos en el Hospital de San José entre el 2002 y 2005, por tres cirujanos. Se utilizo técnica de pequeña fenestración realizada con perforadores manuales; 48 casos cumplieron con los criterios. Se excluyeron los casos de revisión, aquellos con anomalías anatómicas o datos inadecuados pre o postquirúrgicos. Se midió el gap óseo-aéreo con audiometría de tonos puros en cuatro frecuencias y el umbral límite de pérdida auditiva neurosensorial, tomando como base para evaluar los resultados el PTA (promedio tonal auditivo). Resultados: se agruparon 33 casos con prótesis de teflón y 15 de titanio. El cierre del gap óseo-aéreo menor o igual a 10 db fue del 80% para los casos de titanio y del 76% para los de teflón. La pérdida auditiva neurosensorial fue baja para ambos grupos sin diferencia significativa. Discusión: los resultados fueron similares para ambos grupos, pero se observó que la prótesis de titanio fue levemente superior. Los resultados descritos concuerdan con los reportados en la literatura, que muestran un rango en el cierre del gap óseo-aéreo menor de 10 db del 71% al 94%. El número pequeño de casos o la predilección por una de las prótesis puede influenciar el resultado descrito.


Subject(s)
Humans , Male , Female , Adolescent , Aged , Case Reports , Otosclerosis/surgery , Correction of Hearing Impairment/methods , Otologic Surgical Procedures/methods , Auditory Perceptual Disorders/surgery
SELECTION OF CITATIONS
SEARCH DETAIL